BTU Calculator
A BTU calculator for air conditioners, mini-splits and heaters: enter the room and see the BTU per hour it needs, in tons and kilowatts too.
- Checked
- 4 sources
- Formula tested
- Works offline
Results
Unit size
- Mini-split / AC size to buy (next size up)
- 9,000 BTU
- In tons of cooling
- 0.67 tons
- In kilowatts
- 2.34 kW
- Electric heater size
- – W
- Floor area
- 300 sq ft
Where the heat goes
- Through the walls
- – BTU/hr
- Through the windows
- – BTU/hr
- Through the ceiling
- – BTU/hr
- Air leaks
- – BTU/hr
On this page 12 sections
- How many BTU do I need for my room?
- Worked example: cooling a 20 × 15 ft bedroom
- AC BTU chart by room size
- Heating BTU calculator: how much heat does a room need?
- Garage heater BTU calculator
- Mini-split BTU calculator: which size to buy
- BTU to tons, kW and watts
- How to calculate BTU by hand
- Frequently asked questions
- Related calculators
- Sources and method
- Add this calculator to your website
How many BTU do I need for my room?
For cooling, ENERGY STAR sizes a room air conditioner by floor area: about 20 BTU per square foot for a mid-size room, from 5,000 BTU for 100 to 150 sq ft up to 34,000 for 2,500 sq ft. A 20 × 15 ft bedroom (300 sq ft) needs 8,000 BTU per hour, so buy a 9,000 BTU mini-split or the nearest window unit. Heating depends on insulation and how cold it gets, so pick "Heating" above for a heat-loss estimate.
Worked example: cooling a 20 × 15 ft bedroom
- Floor area: 20 × 15 = 300 sq ft.
- ENERGY STAR chart: 300 up to 350 sq ft needs 8,000 BTU per hour.
- Adjust: average sun and two people, so nothing is added. A very sunny room would add 10% (8,800); each extra person adds 600 BTU.
- Convert: 8,000 ÷ 12,000 = 0.67 tons; 8,000 ÷ 3,412 = 2.34 kW.
- Buy: mini-splits come in 6,000, 9,000, 12,000 BTU and up, so the next size up is 9,000 BTU.
AC BTU chart by room size
ENERGY STAR's room air conditioner sizes for an average room with two people. Add 10% for a very sunny room, take off 10% for a heavily shaded one.
| Room | Area | BTU per hour | Tons | Mini-split size |
|---|---|---|---|---|
| 10 × 10 ft | 100 sq ft | 5,000 | 0.42 | 6,000 |
| 12 × 12 ft | 144 sq ft | 5,000 | 0.42 | 6,000 |
| 12 × 15 ft | 180 sq ft | 6,000 | 0.5 | 6,000 |
| 15 × 20 ft | 300 sq ft | 8,000 | 0.67 | 9,000 |
| 20 × 20 ft | 400 sq ft | 10,000 | 0.83 | 12,000 |
| 20 × 25 ft | 500 sq ft | 12,000 | 1 | 12,000 |
| 25 × 30 ft | 750 sq ft | 18,000 | 1.5 | 18,000 |
| 30 × 40 ft | 1,200 sq ft | 23,000 | 1.92 | 24,000 |
| 40 × 50 ft | 2,000 sq ft | 34,000 | 2.83 | 36,000 |
In a kitchen, add 4,000 BTU for the heat from cooking. ENERGY STAR's chart stops at 2,500 sq ft; a whole house needs a Manual J load calculation from an HVAC contractor.
Heating BTU calculator: how much heat does a room need?
A heater has to replace the heat a room loses, and that depends far more on insulation and the outdoor temperature than on floor area. The calculator adds up four losses, using the method in University of Minnesota Extension's Residential Heat Loss:
- Walls, windows and ceiling: area ÷ R-value × (inside − outside temperature), for each surface.
- Air leaks: 0.018 × room volume × air changes per hour × (inside − outside temperature). 0.018 BTU heats one cubic foot of air by 1 °F.
Heating BTU for rooms 8 ft high with two outside walls, windows equal to 12% of the floor, an attic above, 70 °F inside and 10 °F outside:
| Room | No insulation | Some (older house) | Energy code | Very well insulated |
|---|---|---|---|---|
| 10 × 10 ft | 8,620 | 2,779 | 1,274 | 1,076 |
| 12 × 12 ft | 11,749 | 3,786 | 1,714 | 1,448 |
| 12 × 15 ft | 14,316 | 4,619 | 2,084 | 1,763 |
| 15 × 20 ft | 22,472 | 7,246 | 3,222 | 2,727 |
| 20 × 20 ft | 29,058 | 9,371 | 4,136 | 3,502 |
| 20 × 25 ft | 35,645 | 11,495 | 5,049 | 4,278 |
That is why "BTU per square foot" rules of thumb vary so much: the same 12 × 15 ft room needs about 2,100 BTU when built to code and more than 14,000 with no insulation at all.
Garage heater BTU calculator
Garages are often uninsulated, have a big door and are heated to a working temperature rather than a living one. For a detached garage with no windows, 8 ft walls, kept at 50 °F when it is 10 °F outside:
| Garage | No insulation | Some insulation | Insulated to code |
|---|---|---|---|
| 12 × 22 ft (1 car) | 15,512 BTU (4,546 W) | 4,815 BTU (1,411 W) | 2,126 BTU (623 W) |
| 20 × 20 ft (2 car) | 21,420 BTU (6,278 W) | 6,625 BTU (1,942 W) | 2,853 BTU (836 W) |
| 24 × 24 ft (2 car) | 29,110 BTU (8,531 W) | 8,982 BTU (2,632 W) | 3,801 BTU (1,114 W) |
| 32 × 24 ft (3 car) | 37,367 BTU (10,951 W) | 11,511 BTU (3,374 W) | 4,812 BTU (1,410 W) |
In an uninsulated garage most of the heat leaves through the ceiling and air leaks, so insulating the ceiling and sealing the door often shrinks the heater you need more than anything else. Pick "None" insulation and 4 outside walls above for a detached garage, 3 for one attached to the house. A garage with a fuel-burning heater needs the venting and clearances in the heater's manual.
Mini-split BTU calculator: which size to buy
Ductless mini-splits are sold in steps: 6,000, 9,000, 12,000, 15,000, 18,000, 24,000, 30,000 and 36,000 BTU. Work out the room's BTU, then pick the next size up. A much bigger unit is not better: it cools the room before it has taken the moisture out, so the room feels clammy, and it switches on and off more often. One head per room usually beats one large head for a whole floor, because walls stop the air from spreading.
BTU to tons, kW and watts
- Tons: 1 ton of cooling = 12,000 BTU per hour. A "2-ton" AC is 24,000 BTU.
- Kilowatts: 1 kW = 3,412 BTU per hour (U.S. Energy Information Administration). 12,000 BTU is 3.52 kW.
- Electric heater watts: BTU ÷ 3.412. A 1,500 W plug-in heater gives about 5,118 BTU per hour.
An AC's BTU rating is the heat it removes, not the electricity it uses. Its power draw is much lower, set by its efficiency (EER or SEER2).
How to calculate BTU by hand
- Measure the floor: length × width in feet. Split an L-shaped room into rectangles and add them.
- Cooling: look up the area in ENERGY STAR's chart above, adjust 10% for sun or shade, add 600 BTU per person over two and 4,000 for a kitchen.
- Heating: for each outside wall, window and the ceiling, divide its area by its R-value and multiply by the temperature difference. Add 0.018 × volume × air changes × the temperature difference for air leaks.
- Round up to the next unit size you can buy.
Frequently asked questions
How many BTU do I need per square foot?
What size air conditioner do I need for a 12 × 12 room?
How many BTU does a 2-car garage heater need?
How many square feet does a 12,000 BTU mini-split cool?
How many BTU is 1 ton?
How do I convert BTU to kW?
Is a bigger AC better?
Related calculators
Sources and method
- ENERGY STAR — Room Air Conditioners: how to choose the right size — BTU per hour by area (100 to 2,500 sq ft); −10% heavily shaded, +10% very sunny, +600 BTU per person over two, +4,000 BTU in a kitchen
- University of Minnesota Extension — Residential Heat Loss — heat loss = area ÷ R-value × temperature difference; infiltration = 0.018 × volume × air changes × temperature difference; R-values and air changes for standard, well-insulated and energy-code houses
- Alaska Housing Finance Corporation — R-Value of Building Materials — air films, drywall, plywood, siding, air space and single glass, summed for the "no insulation" level
- U.S. Energy Information Administration — British thermal units (Btu) — 1 kilowatthour = 3,412 Btu
Last checked November 18, 2026. How we build and test every calculator: methodology.